Table Top Steam Sterilizer Fully Automatic Microcomputer Type Hq-Xd35DV

 MODEL: HQ-XD35DVThe unit disinfects and sterilizes the objects with saturated steam, by the means of pulsely exhausting the cold air to clear the efforts from which to the temperature,and make the objects completely drying by the way of vacuum-exhausting and jacket baking.By using the physical characteristic

Featured Products

 MODEL: HQ-XD35DV

The unit disinfects and sterilizes the objects with saturated steam, by the means of pulsely exhausting the cold air to clear the efforts from which to the temperature,and make the objects completely drying by the way of vacuum-exhausting and jacket baking.By using the physical characteristics of the pressured saturated steam will releasing plenty of hot while condensing,the unit will keep the sterilizing objects wet and at high temperature in a given time ,which spoils the virus and the spores together, and good sterilizing efforts will be received.


PARAMETER
 
Chamber Volume:35Liters
Max working temperature:134ºC±1ºC
Max working pressure:0.22mpa
Adjusted sterilizing temperature range:         55ºC~134ºC
Adjusted  timer range:         1~99mins
Adjusted drying time range:         1~99mins
Vacuum limit:         -0.08mpa
Hot Average:         ≤2ºC
Power supply:    AC220V/50HZ
Dimension:  73550×510 mm
Transport dimension:    81680×650 mm
Gross/Net Weight   90/73 kg
  1. We reserve the right for the modification of the dimension and the weight

   CHARACTERISCTICS:
 
  1. The sterilizing procedure is automatically controlled, it is not necessary to be supervised, and used conveniently.
  2. At lease 3 or more times pulse-vacuum exhausting, which is applied to wrapped or unwrapped objects,hollow equipment.
  3. Drying function.
  4. With inner printer, which record the for the full procedure of the sterilization.
  5. With Bowie&Dick testing function, which is for the steam penetrating testing.
  6. Self-testing malfunction, easy to maintain.
  7. Safety functions:
Safety locking: the steam can not enter the chamber and the unit will alarm when the door is not closed tightly,and the door can not the open when the inner pressure is exceed 0.027mpa.
     Over pressure protection:
     If the pressure exceed the working pressure, the safety valve will exhausting the air.
     Low water protection:
     The unit can not be started if the water don't reach the high level,and the power will cut off directly.
     Over current protection:
     The broker will cut off the power by the over current happened.   

Table Top Steam Sterilizer Fully Automatic Microcomputer Type Hq-Xd35DV


Table Top Steam Sterilizer Fully Automatic Microcomputer Type Hq-Xd35DV



Table Top Steam Sterilizer Fully Automatic Microcomputer Type Hq-Xd35DV

Table Top Steam Sterilizer Fully Automatic Microcomputer Type Hq-Xd35DV
Table Top Steam Sterilizer Fully Automatic Microcomputer Type Hq-Xd35DV



Table Top Steam Sterilizer Fully Automatic Microcomputer Type Hq-Xd35DV


Sales Manager: Miss Abby  
Yiwu Hongqian Technology Industry Co.,Ltd
      
   
 
https://mediconnexbiz.en.made-in-china.com/

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours